E81T1-Ni1 H4

AWS: E81T1-Ni1C-JH4, E81T1-C1A4-Ni1-H4 Flux-cored (FCAW-G) Wire is designed for high strength, low-alloy applications using 100% CO2 shielding gas.

AWS: E81T1-Ni1C-JH4, E81T1-C1A4-Ni1-H4 Flux-cored (FCAW-G) Wire is designed for high strength, low-alloy applications using 100% CO2 shielding gas.
 
Features
Capable of producing weld deposits with impact toughness exceeding 88 - 123 J (65 - 91 ft·lbf) at -40°C (-40°F)
Designed for welding with 100% CO2 shielding gas
Premium arc performance and bead appearance
Meets AWS D1.8 seismic lot waiver requirements
foil bag packaging
 

CONFORMANCES

 SPECIFICATION

 CLASSIFICATION

AWS

AWS A5.29

E81T1-Ni1C-JH4

AWS

AWS A5.36

E81T1-C1 A4-Ni1-H4

ABS

ABS- Part2

4YQ460SA H5

CWB

CSA W48

E551T1-C1A4-Ni1-H4 (E551T1-Ni1C-JH4)

DNV-GL

DNV-2.9 IV

Y46MS H5

LR

LR - Chapter 11

4Y46S H5

 
DEPOSIT COMPOSITION

Classification

Shielding Gas

Polarity

%B

%C

%Cr

%Mn

%Mo

%Ni

%P

%S

%SI

%V

Diffusible Hydrogen
mL/100g Weld Metal

E81T1-Ni1C-JH4

100% CO2

DC+

 

0.12 max.

0.15 max.

1.5 max.

0.35 max.

0.8-1.1

0.03 max.

0.03 max.

0.8 max.

0.05 max.

4.0 max.

E81T1-C1A4-Ni1-H4

100% CO2

DC+

 

0.12 max.

0.15 max.

1.75 max.

0.35 max.

0.8-1.1

0.03 max.

0.03 max.

0.8 max.

0.05 max.

4 max.

Typical Result, As -welded

100% CO2

DC+

0.0050-0.006

0.04-0.05

0.04-0.06

1.12-1.42

0.01

0.81-1

0.012 max.

0.01 max.

0.24-0.35

0.02- 0.03

1.7-3.2

 
NOTES
To estimate ESO, subtract 1/4 in. (6.0 mm) from CTWD.
NOTE 1: FEMA and AWS D1.8 structural steel seismic supplement test data can be found on this product at www.lincolnelectric.com.
NOTE 2: This product contains micro-alloying elements. Additional information available upon request.
 